# Network UPS Tools driver.list # # This file is used to build the compat.html on the web server. Any line # with exactly 4 arguments will be turned into an entry on there. # Naturally, it is read by parseconf, so the usual escaping tricks are # allowed if you need to insert something unusual. # # If you write a new driver, modify an existing one to add more support, # or just know about some equipment that isn't listed but should be, # please send me a patch to update this file. # # The format: # # # # Note that the "upstype=nn" format must be used for genericups entries, # as they will be parsed by new configuration helper software. # # Duplicate text in the last field will be cooked out during the conversion # to HTML with ROWSPAN magic. They must be an exact match for this to work. "APC" "Back-UPS Pro" "" "apcsmart" "APC" "Matrix-UPS" "" "apcsmart" "APC" "Smart-UPS" "" "apcsmart" "APC" "Back-UPS Pro USB" "" "hidups (experimental USB driver for Linux)" "APC" "Back-UPS USB" "" "hidups (experimental USB driver for Linux)" "APC" "Back-UPS LS USB" "" "hidups (experimental USB driver for Linux)" "APC" "Back-UPS ES/CyberFort 350" "" "hidups (experimental USB driver for Linux)" "APC" "Back-UPS" "940-0095A/C cables" "genericups upstype=1" "APC" "Back-UPS" "940-0020B/C cables" "genericups upstype=2" "APC" "Back-UPS" "940-0023A cable" "genericups upstype=9" "APC" "Back-UPS Office" "940-0119A cable" "genericups upstype=12" "APC" "Masterswitch" "Not a UPS - 940-0020 cable" "genericups upstype=12" "APC" "Back-UPS RS 500" "custom non-USB cable" "genericups upstype=20" "APC" "(various)" "SNMP monitoring card" "snmp-ups (experimental driver)" "Belkin" "Regulator Pro" "serial" "belkin" "Belkin" "Resource" "" "genericups upstype=4" "Belkin" "Home Office" "F6H350-SER, F6H500-SER, F6H650-SER" "genericups upstype=7" "Belkin" "Universal UPS" "F6C800-UNV, F6C120-UNV" "belkinunv" "Best Power" "Fortress (newer)" "" "bestups" "Best Power" "Fortress Telecom" "" "bestups" "Best Power" "Axxium Rackmount" "" "bestups" "Best Power" "Patriot Pro" "" "bestups" "Best Power" "Patriot Pro II" "" "bestups" "Best Power" "Patriot" "INT51 cable" "genericups upstype=6" "Best Power" "Micro-Ferrups" "" "bestuferrups" "Best Power" "Fortress/Ferrups" "f-command support" "bestfcom" "Centralion" "Blazer" "" "blazer" "Cyber Power Systems" "700AVR" "" "cyberpower" "Cyber Power Systems" "900AVR" "" "cyberpower" "Cyber Power Systems" "1250AVR" "" "cyberpower" "Cyber Power Systems" "1500AVR" "" "cyberpower" "Cyber Power Systems" "Power99" "" "genericups upstype=7" "Cyber Power Systems" "CPS825VA" "" "cpsups (experimental)" "Cyber Power Systems" "1100AVR" "" "cpsups (experimental)" "Cyber Power Systems" "1500AVR-HO" "" "cpsups (experimental)" "Effekta" "MI/MT/MH" "2502 cable" "fentonups" "Energizer" "(various)" "USB" "energizerups (experimental USB driver for Linux") "Energy Sistem" "(various)" "" "esupssmart" "ETA" "mini+UPS" "WinNT/Upsoft cable" "genericups upstype=7" "ETA" "mini+UPS PRO" "UPS Explorer cable" "etapro" "Ever UPS" "NET *-DPC" "" "everups" "Ever UPS" "AP *-PRO" "" "everups" "Ever-Power" "625/1000" "" "safenet" "Fenton Technologies" "PowerPal" "P-series" "safenet" "Fenton Technologies" "PowerPal" "L-series" "fentonups" "Fenton Technologies" "PowerOn" "" "fentonups" "Fenton Technologies" "PowerPure" "" "fentonups" "Fairstone" "L525/L625/L750" "" "safenet" "Fideltronik" "Ares 700 and larger" "" "genericups upstype=6" "Fideltronik" "Other Ares models" "" "genericups upstype=19" "Gemini" "UPS625/UPS1000" "" "safenet" "Infosec" "iPEL 350" "" "esupssmart" "Infosec" "iPEL 500" "" "esupssmart" "Infosec" "iPEL 750" "" "esupssmart" "Infosec" "iPEL 1000" "" "esupssmart" "Ippon" "(various)" "" "ippon" "Liebert" "UPStation GXT2" "contact-closure cable" "liebert" "Masterguard" "(various)" "" "masterguard" "Meta System" "HF Line" "1..4 boards" "metasys" "Meta System" "HF Line \/2" "5..8 boards" "metasys" "Meta System" "HF Millennium 810" "" "metasys" "Meta System" "HF Millennium 820" "" "metasys" "Meta System" "HF TOP Line 910" "" "metasys" "Meta System" "HF TOP Line 920" "" "metasys" "Meta System" "HF TOP Line 930" "" "metasys" "Meta System" "HF TOP Line 940" "" "metasys" "Meta System" "HF TOP Line 950" "" "metasys" "Meta System" "HF TOP Line 960" "" "metasys" "Meta System" "HF TOP Line 970" "" "metasys" "Meta System" "HF TOP Line 980" "" "metasys" "Meta System" "ECO Network 750" "" "metasys" "Meta System" "ECO Network 1000" "" "metasys" "Meta System" "ECO Network 1050" "" "metasys" "Meta System" "ECO Network 1500" "" "metasys" "Meta System" "ECO Network 1800" "" "metasys" "Meta System" "ECO Network 2000" "" "metasys" "Meta System" "ECO Network 2100" "" "metasys" "Meta System" "ECO Network 2500" "" "metasys" "Meta System" "ECO Network 3000" "" "metasys" "Meta System" "ECO 305" "" "metasys" "Meta System" "ECO 308" "" "metasys" "Meta System" "ECO 311" "" "metasys" "Meta System" "ECO 511" "" "metasys" "Meta System" "ECO 516" "" "metasys" "Meta System" "ECO 519" "" "metasys" "Meta System" "ECO 522" "" "metasys" "Meta System" "ally HF 800" "" "metasys" "Meta System" "ally HF 1000" "" "metasys" "Meta System" "ally HF 1250" "" "metasys" "Meta System" "ally HF 1600" "" "metasys" "Meta System" "ally HF 2000" "" "metasys" "Meta System" "ally HF 2500" "" "metasys" "Meta System" "Megaline 1250" "" "metasys" "Meta System" "Megaline 2500" "" "metasys" "Meta System" "Megaline 3750" "" "metasys" "Meta System" "Megaline 5000" "" "metasys" "Meta System" "Megaline 6250" "" "metasys" "Meta System" "Megaline 7500" "" "metasys" "Meta System" "Megaline 8750" "" "metasys" "Meta System" "Megaline 10000" "" "metasys" "MGE UPS SYSTEMS" "Protection Center" "" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "Pulsar Ellipse USBS" "USB cable" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "Pulsar Ellipse USB" "" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "Pulsar Ellipse Premium USBS" "USB cable" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "Pulsar Ellipse Premium USB" "" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "Pulsar Evolution" "USB port" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "Comet / Galaxy (USB)" "USB Card (ref 66067)" "newhidups or hidups (experimental USB drivers)" "MGE UPS SYSTEMS" "NOVA AVR Serial" "" "mge-shut" "MGE UPS SYSTEMS" "Pulsar Ellipse USBS" "Serial cable" "mge-shut" "MGE UPS SYSTEMS" "Pulsar Ellipse S" "" "mge-shut" "MGE UPS SYSTEMS" "Pulsar Ellipse Premium USBS" "Serial cable" "mge-shut" "MGE UPS SYSTEMS" "Pulsar Ellipse Premium S" "" "mge-shut" "MGE UPS SYSTEMS" "Pulsar Evolution" "Serial port" "mge-utalk or mge-shut" "MGE UPS SYSTEMS" "Pulsar ESV+" "" "mge-utalk" "MGE UPS SYSTEMS" "Pulsar ESV" "" "mge-utalk" "MGE UPS SYSTEMS" "Pulsar EX" "" "mge-utalk" "MGE UPS SYSTEMS" "Pulsar EXL" "" "mge-utalk" "MGE UPS SYSTEMS" "Pulsar SX" "" "mge-utalk" "MGE UPS SYSTEMS" "Pulsar ES+" "" "mge-utalk" "MGE UPS SYSTEMS" "Pulsar Esprit" "" "mge-shut" "MGE UPS SYSTEMS" "Pulsar EXtreme C" "" "mge-utalk or mge-shut" "MGE UPS SYSTEMS" "Pulsar / Comet EXtreme" "" "mge-utalk" "MGE UPS SYSTEMS" "Comet / Galaxy (Serial)" "Utalk Serial Card (ref 66060)" "mge-utalk" "MGE UPS SYSTEMS" "Comet / Galaxy (Serial)" "HID COM Serial Card (ref 66066)" "mge-shut" "MGE UPS SYSTEMS" "Pulsar / Comet / Galaxy (SNMP)" "SNMP/Web Transverse card (ref 66074)" "snmp-ups (experimental)" "MGE UPS SYSTEMS" "Pulsar (SNMP)" "SNMP/Web Minislot card (ref 66244)" "snmp-ups (experimental)" "MGE UPS SYSTEMS" "Pulsar / Comet / Galaxy (SNMP)" "SNMP card (ref 66062)" "snmp-ups (experimental)" "MGE UPS SYSTEMS" "Pulsar (SNMP)" "SNMP card (ref 66045)" "snmp-ups (experimental)" "MGE UPS SYSTEMS" "UM-Link (SNMP)" "Not a UPS (ref 66850)" "snmp-ups (experimental)" "Mustek" "Various" "" "mustek" "Mustek" "Powermust" "400VA Plus" "powermust" "Mustek" "Powermust" "600VA Plus" "powermust" "Mustek" "Powermust" "800VA Pro" "powermust" "Mustek" "Powermust" "1000VA Plus" "powermust" "Nitram" "Elite 500" "" "genericups upstype=8" "Nitram" "Elite 2002" "" "genericups upstype=16" "Oneac" "EG/ON Series" "advanced interface" "oneac" "Online" "P-Series" "" "genericups upstype=14" "OnLite" "AQUA" "50" "powermust" "Orvaldi Power Protection" "various" "not 400 or 600" "fentonups" "Powercom" "SMK-800A" "" "fentonups" "Powercom" "ULT-1000" "" "fentonups" "Powercom" "Trust 425/625" "" "powercom" "Powercom" "(various)" "" "powercom" "Powercom" "Advice Partner/King Pr750" "" "powercom" "PowerGuard" "PG-600" "" "fentonups" "PowerKinetics" "9001" "" "genericups upstype=17" "PowerTech" "Comp1000" "DTR cable power" "genericups upstype=3" "Powerware" "3115" "" "genericups upstype=11" "Powerware" "5119, 5125" "" "genericups upstype=15" "Powerwell" "PM525A/-625A/-800A/-1000A/-1250A" "" "safenet" "Repotec" "RPF525/625/800/1000" "" "safenet" "Repotec" "RPT-800A" "" "genericups upstype=13" "Repotec" "RPT-162A" "" "genericups upstype=13" "SMS (Brazil)" "Manager III" "" "sms" "SOLA" "325" "" "bestups" "SOLA" "520" "" "bestups" "SOLA" "610" "use ID= in ups.conf" "bestups" "SOLA" "620" "" "bestups" "SOLA" "330" "" "blazer" "SOLA/BASIC Mexico" "various" "ISBMEX protocol" "isbmex" "Socomec Sicon" "Egys" "420 VA" "powercom" "Soltec" "Winmate 525/625/800/1000" "" "safenet" "SuperPower" "HP360, Hope-550" "" "fentonups" "Sweex" "500/1000" "smart - shipped with SafeNet" "safenet" "Sweex" "500/1000" "contact closure - shipped with UPSmart" "genericups upstype=7" "Tripp-Lite" "SmartUPS" "" "tripplite" "Tripp-Lite" "SmartOnline" "" "tripplitesu" "Tripp-Lite" "(various)" "Lan 2.2 interface - black 73-0844 cable" "genericups upstype=5" "UNITEK" "ALPHA 500 IC" "" "fentonups" "UNITEK" "Alpha 1000is" "" "fentonups" "UPSonic" "LAN Saver 600" "" "genericups upstype=0" "UPSonic" "Power Guardian" "" "genericups upstype=7" "Various" "(various)" "Generic RUPS model" "genericups upstype=4" "Various" "(various)" "Megatec protocol" "fentonups" "Various" "(various)" "PhoenixTec protocol" "bestups" "Various" "(various)" "SNMP - RFC 1628" "snmp-ups (experimental)" "Various" "(various)" "Safenet software" "safenet" "Victron/IMV" "(various)" "" "victronups" "Victron/IMV" "Lite" "crack cable" "genericups upstype=10"